An assembly of power capacitors connected in a three-phase arrangement and switched onto the ship's busbar to supply reactive power (kVAR) locally, offsetting the lagging reactive current drawn by induction motors and other inductive loads, raising the overall system power factor, reducing the reactive current burden on generators and cables, and increasing the effective active power (kW) capacity available from a given set of generators. Capacitor banks must be carefully sized and switched to avoid resonance with the system inductance at harmonic frequencies and to prevent excessive voltage transients when they connect to a partially loaded bus.