A selective corrosion process that affects copper-zinc alloys (brasses) in which zinc is preferentially dissolved from the alloy matrix by sea water or other corrosive media, leaving behind a porous, mechanically weak residue of copper that retains the external shape of the original fitting but has lost most of its strength and pressure-holding capability. The process can propagate through the wall of a valve body, pipe fitting, or pump casing without obvious external damage, and the affected region is typically identified by its pink or red colour compared to the normal yellow-gold of the original brass. Using dezincification-resistant (DZR) brasses — inhibited with small additions of arsenic — or selecting alternative alloys such as bronze or copper-nickel for sea water service fittings is the standard preventive measure to avoid this mode of failure.