A combined I/P converter and valve positioner in a single integral unit that accepts a 4–20 mA electrical input directly from the controller, compares it to the measured valve stem position, and directly drives the actuator air supply to close the position loop without a separate I/P converter; HART (Highway Addressable Remote Transducer) or fieldbus communication capability is usually incorporated, allowing the positioner to transmit its position readback, diagnostic data, and valve signature information digitally to the automation system. Electropneumatic positioners are the standard final-control-element interface on modern marine automation systems, replacing the earlier arrangement of separate I/P converter plus pneumatic positioner.