A large tank into which fuel oil is pumped from the main bunker tanks and left to stand so that free water and heavy solids settle to the bottom by gravity before the cleaner oil above is drawn off for purification. The settling period — typically 12 to 24 hours — allows bulk water separation before the centrifugal purifiers, reducing the water load on the separator and improving purification efficiency.