Engineering/Technical

The main isolation valve on the boiler steam outlet used to connect or disconnect that boiler from the common steam header. When bringing a boiler on line alongside an already running boiler, the steam stop valve must be opened only after the new boiler's drum pressure has been raised to match the header pressure, preventing a pressure surge into the header or a sudden steam reversal that could collapse drum water level.