A self-acting device fitted at the outlets of steam heaters, heating coils, and steam-traced piping that automatically discharges condensate and air while preventing live steam from bypassing the heating surface. A failed-open steam trap wastes heat energy and increases boiler load; a failed-closed trap allows condensate to flood the heating surface, reducing heat transfer efficiency and creating the risk of water hammer damage when hot steam contacts a slug of accumulated water.