An automatic alarm system required on vessels with UMS (unmanned machinery space) notation that resets at a defined time interval — typically 15 or 30 minutes — only when a responsible person physically acknowledges it at a local reset point in the machinery space, providing assurance that a duty engineer is physically present and aware in the engine room during unmanned watch periods; if the alarm is not acknowledged within the required time, it triggers an escalating series of alerts that ultimately wakes a senior engineer. The watchkeeping alarm system is a classification society requirement for UMS notation and is tested regularly to confirm it is operational.