Wound Rotor Motor

Engineering/Technical

An AC induction motor variant in which the rotor carries a conventional three-phase winding brought out through slip rings to external terminals, allowing external resistors to be inserted in the rotor circuit during starting to limit starting current, increase starting torque, and control speed; as the motor accelerates, the external resistance is progressively reduced until the rotor is short-circuited for full-speed running. Wound rotor motors are used on ships for heavy-duty applications requiring high starting torque under load — deck cranes, cargo winches, large air compressors — where a squirrel-cage motor would either draw excessive current or fail to develop sufficient starting torque.